Product Center

Standard gas for calibration of gas detection alarms

Packaging: 1-8L bottle

Standard filling pressure: 9.5 MPa

Product Details

1. Standard gas for calibration of combustible gas detection alarms
No.NameComposition concentrationBalance gasSpecificationsPurpose
1Methane calibration standard gas

CH4: 0.5∽3%

(10%LEL∽60%LEL)

Air2L、4L、8LCalibrate the combustible gas transmitter
2Propane calibration standard gas

C3H8: 0.22∽1.32%

(10%LEL∽60%LEL)

Air2L、4L、8L
3Butane calibration standard gas

C4H10: 0.19∽1.14%

(10%LEL∽60%LEL)

Air2L、4L、8L
4Isobutane calibration standard gas

i-C4H10: 0.18∽1.08%

(10%LEL~60%LEL)

Air2L、4L、8L
5Ethanol calibration standard gas

C2H5OH: 0.033∽1.65%

(1%LEL∽50%LEL)

Air2L、4L、8L
[Note]: According to the verification regulation of combustible gas detection alarm, if the type of detected gas is not indicated, Isobutane or propane standard gas can be used for calibration (k=2, u ≤ 2%)
2. Standard gas for calibration of toxic gas detection alarms
No.NameComposition concentrationBalance gasSpecificationsPurpose
1Carbon monoxide calibration standard gasCO: 1∽1000ppmNitrogen or air2L、4L、8LCalibrate toxic gas alarm
2Nitric oxide calibration standard gasNO: 1~250ppmNitrogen2L、4L、8L
3Nitrogen dioxide calibration standard gasNO2: 1∽20ppmNitrogen or air2L、4L、8L
4Hydrogen sulfide calibration standard gasH2S: 1∽100ppmNitrogen or air2L、4L、8L
5Sulfur dioxide calibration standard gasSO2: 1∽20ppmNitrogen or air2L、4L、8L
6Chlorine calibration standard gasCl2: 1~100ppmNitrogen or air2L、4L、8L
7Vinyl chloride calibration standard gasC2H3CI: 1∽10ppmNitrogen or air2L、4L、8L
8Phosphine calibration standard gasPH3: 0.1∽1ppmNitrogen2L、4L、8L
9Cyanide calibration standard gasHCN: 1∽5ppmNitrogen2L、4L、8L
10Ethylene oxide calibration standard gasC2H4O: 1∽100ppmNitrogen2L、4L、8L
11Benzene calibration standard gasC6H6: 1~100ppmNitrogen or air2L、4L、8L
12Ammonia calibration standard gasNH3: 1∽100ppmNitrogen or air2L、4L、8L
3. Standard gas for calibration of oxygen and carbon dioxide gas detection alarms
No.NameComposition concentrationBalance gasSpecificationsPurpose
1Oxygen calibration standard gasO2: 1∽30%VOLNitrogen2L、4L、8LCalibrate oxygen alarm
2Carbon dioxide calibration standard gasCO2: 1∽5%VOLNitrogen2L、4L、8LCalibrate carbon dioxide and nitrogen alarms
4. Standard gas for calibration of gas detection alarms - zero point gas
No.NameComposition concentrationBalance gasSpecificationsPurpose
1Zero point gas airClean air-2L、4L、8LZero calibration
2Zero point gas - nitrogen gasN2≥99.99%-2L、4L、8L